Product Class
Handheld Pulse Oximeter
  NT1A
  NT1D
Handheld CO2/SpO2 Monitor
  NT1D Series
Vital Signs Monitors
  NT2A
  NT2C
Monitoring Accessories
  SpO2 Sensors
  NIBP Cuffs
  ECG Cables
  Temperature Sensors
>> Contact Us
427 26th Avenue,
Ste. 101
San Francisco
CA 94121, USA
TEL: (415) 666 3980
FAX: (415) 666 3908
E-mail:
sales@solarismedtech.com
Product -- NT2C (CE Marked)
NT2C Portable Vital Signs Monitor
Product Description:

◆Bright, Easy-to-Read Large LED Display
◆Durable, Compact and Lightweight
◆Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
◆Bright, Easy-to-Read Large LED Display
◆Durable, Compact and Lightweight
◆Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
◆Audible/Visual Three Level Alarms with Alarm Volume Control
◆72-hour Data Memory Allowing On-screen data replay
◆Suitable for Adult, Pediatric and Neonate
◆Optional Internal Thermal Recorder


Product Features :

◆Performance Measurement Range:
SpO2: 0%-100%
Pulse Rate: 30bpm~250bpm

◆SpO2 Accuracy:
Adults, Pediatrics: 70%-100% ±2%
                    0%-69% unspecified
     Neonates:      70%-100% ±3%
                    0%-69% unspecified
◆Pulse Rate Accuracy
Adults, Pediatrics, Neonates: ±3%

◆ECG
ECG cable: 5 Lead ECG Cable
Lead selection:Ⅰ,Ⅱ, Ⅲ/ aVR,  aVL,  aVF/ V
Gain (mm/mV): 1/4, 1/2,1, 2, 4, Manual/Automatic
Sweep speed (mm c):  6.25, 12.5, 25, 50
Heart rate range: 30-300bpm
Heart rate accuracy:±1bpm or ±1 %
ST segment analysis (Diagnostic mode):
    a. ST range: -2.0mV-+2.0mV
    b. ST accuracy:±0.02mV
Monitoring mode: Diagnostic    0.05-100Hz
                               Monitoring     0.5-40 Hz
                               Operating      1.0-25 Hz

◆Non-Invasive Blood Pressure:
Measurement   type:  Adult, Pediatric, Neonatal
Measurement range:
Adult:            Systolic    40-270mmHg
                  Diastolic   20-200mmHg
                  Mean        30-220mmHg
Pediatric:        Systolic    40-180mmHg
                  Diastolic   15-160mmHg
                  Mean        20-170mmHg
Neonatal:         Systolic    30-140mmHg
                  Diastolic   15-100mmHg
                  Mean        20-115mmHg
Accuracy:  Meets ANSI/AAMI SP10-1992
Resolution: 1mmHg
Protection:  over pressure

◆Alarm
Audible/visual Alarms
Adjustable Alarm Limits

◆Temperature:
Measurement range: 25 ~ 45 ℃
Accuracy:  ± 0.2 ℃

◆Output:
RS-232 Serial Port for Digital Output
Nurse Call Function

◆Electrical Instrument:
Power Requirements: 100~240VAC, 50/60Hz, 40VA
Fuse Rating:        1.0A

◆Battery:
Internal Battery:   12V
Battery Capacity:     24 hours

◆Environment:
Operating:
Temperature: 5OC~40OC (41OF ~104OF)
Humidity:    10%~95%            
Transport/Storage:
Temperature: -20OC~70OC (-4OF ~158OF)
Humidity:    10%~95%

◆Physical Characteristics:
Dimensions:    264mm(W) x 95mm(H) x 172mm(D)
               10.39in(W) x 3.74in(H) x 6.77in(D)
Net Weight:      2.25kg/5 Ib

◆Compliance:
1. SpO2: ISO 9919: 2005(E)
2. Safety Standards:
    EN 60601-1: 1990+A1: 1993+A2: 1995+A13: 1996
3. Alarm: IEC60601-1-8: 2005
4. EMC: EN 60601-1-2: 2007, Group 1 Class A
5. Environment : WEEE (2002/96/EC)







 
   
Copyright  ©  2016  Solaris Medical Technology, Inc.